THERMO KING TRIPAC 3

Plan the installation.
Make it your own.

Show us your truck, your available space, and where you want the components. We’ll review your preferences together before installation.

Start Your Guide Finish with a personalized guide you can print or save.
TRIPAC 3 AUXILIARY POWER UNITFront view of a Thermo King TriPac 3 auxiliary power unit

BUILT AROUND YOUR TRUCK
PLANNED FOR YOUR ROUTE.

YOUR TRUCK. YOUR INSTALLATION.

Start with the details that matter.

Use the Thermo King drawings to explore the components, measure your space, and show us your preferred locations. Your installer will confirm the final fit and installation.

Have a tape measure handy.Frame space and the areas behind the cab and under the bunk are useful places to start.

TRUCK DETAILS

Tell us about your truck.

We’ll use these details to prepare for your installation.

This helps our team identify the appropriate TriPac 3 configuration.

THE SPACE ON YOUR TRUCK

Measure your frame rail.

Measure the continuous clear length where the APU could mount. Include obstructions such as steps, tanks, boxes, brackets and fairings.

MEASURE THE CLEAR LENGTHExisting equipmentExisting equipmentFRAME RAIL
PRELIMINARY FRAME-SPACE GUIDELINE26 inches

Measure the clear length along the rail—not the width of the APU housing.

The 26-inch guideline is a starting point, not a fit guarantee. The installer will check the APU envelope, mounting points, exhaust, airflow, service access and other clearances.

Enter a measurement or ask us for help measuring.
What is near the mounting area?

SHOW US YOUR PREFERENCES

Where should the components go?

Choose a component, then tap or click the drawing to mark an approximate location. Add measurements or notes below. Your installer will confirm the final layout.

Choose a side to set your preferred mounting side. You can also mark an alternate position on the other side.

APU MOUNTING LOCATION

Passenger side

Tap the frame area to show your preferred location.
Illustrative straight-on passenger-side view of a sleeper tractor

The usual passenger-side location is shown as a starting point. Tap the frame to move it.

26 inPreliminary clear frame-rail guideline
29.28 inAPU span shown on the component drawing
View APU dimensions

Truck views are illustrations, not scale drawings of your truck. Your marks show preferences; the installer will confirm fit, clearances and the final locations.

Describe your locations.

For example: “Controller beside the bunk, above the existing switches.” Include measurements from a recognizable reference point if you have them.

For a connection to the truck’s existing A/C ducts, ask the installer about the Backflow Preventer Kit. Heater ducting is reviewed separately.

TRIPAC 3 COMPONENTS

Know what needs to fit.

These drawings come from Thermo King’s TriPac 3 documentation. Select a drawing to enlarge it.

Dimensions describe the illustrated components, not the space needed for installation. Brackets, hoses, wiring, ventilation and service access require additional review.

View all TriPac 3 component dimensions

EQUIPMENT FOR YOUR TRUCK

Choose your options.

Select what you’re interested in. Our team will confirm compatibility and availability.

120-amp alternatorStandard equipment on the TriPac 3.
Options of interest

TRIPAC CONNECTIVITY

TracKing telematics

TracKing telematics is available. Contact our sales team for details.

OPERATING PREFERENCES

TriPac 3 settings.

Review the factory settings or request changes that fit your operation. Our installer will confirm your unit’s software and settings.

Thermo King TriPac 3 color in-cab controller
TriPac 3 in-cab controllerChoose a convenient location in the sleeper using the placement drawing above.
Review and adjust factory settingsFactory defaults loaded

The boxes start with documented TriPac 3 defaults. Change a value only if you want to request something different. The installer will verify the installed software and actual settings. Arctic values apply only when that package is installed.

When truck battery voltage drops to this level, the APU can start to recharge the batteries. Your installer checks this against the truck’s low-voltage settings.
Range: 9.0–14.0 V in 0.1 V steps
Factory default: 12.2 V
When charging current falls to this value, the APU may shut down if no other condition requires it to run. A lower value generally allows more charging time.
Range: 12–50 amps in 1-amp steps
Factory default: 20 amps
How far the sleeper temperature rises above the chosen cooling setting before cooling starts again. A higher number allows more temperature variation.
Range: 1–5°F in 1°F steps
Factory default: 2 °F
Extra time the APU continues running after charging current reaches the shutoff value. Other demands, such as cooling, can keep it running longer.
Range: 1–60 minutes in 1-minute steps
Factory default: 1 minute
The lowest temperature the driver can select in Heat mode. This is a limit on the control, not the temperature automatically selected.
Range: 50–90°F in 1°F steps
Factory default: 50 °F
The highest temperature the driver can select in Heat mode. It must be at least as high as the lowest heat setting.
Range: 50–90°F in 1°F steps
Factory default: 80 °F
The lowest temperature the driver can select in Cool mode. This is a limit on the control, not the temperature automatically selected.
Range: 50–90°F in 1°F steps
Factory default: 65 °F
The highest temperature the driver can select in Cool mode. It must be at least as high as the lowest cool setting.
Range: 50–90°F in 1°F steps
Factory default: 80 °F
A limit on how long Cool, Heat or Fan mode can run before that climate mode ends. Disabled means this timer does not limit the mode.
Range: Disabled, or 8–16 hours in 1-hour steps
Factory default: Disabled
Yes returns the unit to monitoring with climate control off after standby. No returns it to the previous climate mode. A Thermo King bulletin specifies Yes for software 5.0.7, while another TriPac 3 manual lists No. The installer will confirm the setting for this unit.
Range: Yes or No
Factory reference: Yes for software 5.0.7; installer confirms
The minimum time the APU engine will remain running after it is requested to start. Zero means no additional minimum is set.
Range: 0–60 minutes in 5-minute steps
Factory default: 0 minutes
The minimum time the APU engine remains off after shutting down. Zero means no additional minimum is set.
Range: 0–60 minutes in 5-minute steps
Factory default: 0 minutes
With the Arctic package installed, this is the returning truck-engine coolant temperature below which the system requests engine warming.
Range: 14–50°F in 1°F steps
Factory default: 32 °F
With the Arctic package installed, this is how much the returning engine coolant temperature must rise above the Arctic start temperature before that warming request ends.
Range: 9–36°F in 1°F steps
Factory default: 18 °F

EXTENDED WARRANTY

Extended warranty options.

Your sales representative will confirm the exact plan, eligibility, terms and pricing.

Additional protection of interest

Our team will confirm whether each plan applies to your equipment, including configurations with ATD.

LET’S PLAN YOUR INSTALLATION

Where should we reach you?

We’ll use these details to follow up about your guide.

YOUR PERSONALIZED GUIDE

TriPac 3 configuration

If the preview doesn’t appear, choose Open / Print or Download PDF.